Innovative 3D Power Module Defaults Detection via Thermal Impedance Analysis and Simulations - Equipe Intégration de Systèmes et Gestion de l'Energie
Communication Dans Un Congrès Année : 2024

Innovative 3D Power Module Defaults Detection via Thermal Impedance Analysis and Simulations

Résumé

This article presents a method for detecting physical defects in an innovative 3D Silicon (Si) power module by measuring thermal impedance (Zth). A non-invasive method for measuring the junction temperature of dies is introduced (voltage drop across a diode under constant current), and a comparison is made with simulation results (CELSIUS EC SOLVER software). The observed differences are analyzed to propose hypotheses for defects origins and location. A scanning electron microscopy (SEM) observation is also used to validate these hypotheses. The results confirm that the comparison between experimental and simulation data of Zth is a precise method for determining the areas of physical defects.
Fichier principal
Vignette du fichier
2024-ALAUZET LOUIS-PCIM.pdf (977.06 Ko) Télécharger le fichier
Origine Fichiers produits par l'(les) auteur(s)

Dates et versions

hal-04810047 , version 1 (02-12-2024)

Identifiants

  • HAL Id : hal-04810047 , version 1

Citer

Louis Alauzet, Jean-Pierre Fradin, Alexandre Dezalay, Anne Castelan, Patrick Tounsi, et al.. Innovative 3D Power Module Defaults Detection via Thermal Impedance Analysis and Simulations. PCIM Europe 2024 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management, Jun 2024, Nuremberg, Germany. ⟨hal-04810047⟩
0 Consultations
0 Téléchargements

Partager

More